TEST Item
|
Test Condition
|
Evaluation Item
|
|
High Temperature Test
|
The specimens are subject to 80°C for 90 minutes.
|
Standard Item
According note 2
|
|
Low Temperature Test
|
The specimens are subject to -30°C for 90 minutes.
|
Standard Item
According note 2
|
|
Heat Cycle Test
|
-40°C 2Hß
à
( 2H ) ß
à
85°C 2H. 30 cycles, then stored at standard evaluation condition for more then 2 hours.
|
Standard Item
According note 2
|
|
Heat/Humidity Cycle Test |
5 cycles, then stored at standard evaluation condition for 60±10 minutes.
|
Standard Item
According note 2
|
|
Thermal Shock Test
|
-40°C 2Hß
à
(5 minutes) ß
à
85°C 2H. 30 cycles, then stored at standard evaluation condition for more than 2 hours.
|
Standard Item
According note 2
|
|
High Temperature Storage Test
|
The specimens are subject to 85°C for 96 hours, then stored at standard evaluation condition for more than 2 hours.
|
Standard Item
According note 2
|
|
Low Temperature storage Test
|
The specimens are subject to -40°C for 72 hours, then stored at standard evaluation condition for more than 2 hours.
|
Standard Item
According note 2
|
|
Water proofing
Test
|
The specimens are subject to 80°C for 1 hours, then sprays water at more than 600mm/H for 1 hour, then stored at Standard evaluation condition for more than 2 hours.
|
Standard Item
According note 2
|
|
Moisture Resistance Test
|
The specimens are subject to 60°C, 90%RH for 96 hours, then stored at standard evaluation condition for more than 2 hours.
|
Standard Item
According note 2
|
|
Heat/Vibration Test
|
Vibration : 33 to 50 Hz 15 min, sweep 1 G for 4 hours
Heat Cycle: -40°C 25 min ß
à
5 min ß
à
85°C 25 min, 4 cycles then stored at standard evaluation condition for more than 2 hours.
|
Standard Item
According note 2
|
|
Weather Resistance Test
|
The specimens are subject to below conditions in a sunshine weather meter, then stored at standard evaluation condition for more than 2 hours.
Temperature of black panel: 63±3°C
Rain: 12 minutes/60 minutes
Nozzle: Φ1mm
Water pressure at the Nozzle: 0.8 to 1.3 kg/sq.cm
Light radiation: 1200 hours
|
Standard Item
According note 2
|
|
High Temperature Test (operation)
|
The specimens are subject to DC 6.0V at 80°C for 120 hours, then stored at standard evaluation condition for more than 2 hours.
|
Standard Item
According note 2
|
|
Low Temperature Test (operation)
|
The specimens are subject to DC 4.5V at –40°C for 72 hours, then stored at standard evaluation condition for more than 2 hours.
|
Standard Item
According note 2
|
|
Salt Atmosphere Test
|
Spray 5±1% NaCl solvent (35±2°C) to the specimens for 16 then stop spraying 8 hours for 20 cycles.
|
Standard Item
According note 2
|
|
Package Drop Test
|
Packaged specimens are dropped on a common floor from 1m height in each direction along six surface, 3 mutually perpendicular and one corner.
|
Standard Item
According note 2
|
|
Long Time Operating Test
|
The specimens are subject to DC 3.3V more than 1000 hours, then stored at standard evaluation condition for more than 2 hours.
|
Standard Item
According note 2
|
|
Static Electrical Resistance Test
|
Adding ±10kV to every touchable place at 10 times, then stored at standard evaluation condition.
|
Standard Item
According note 2
|